当前位置:上海鼎徵仪器仪表设备有限公司>>蒸汽喷射试验箱>> Ford FLTM BI107-05涂层附着力热冲击试验机

Ford FLTM BI107-05涂层附着力热冲击试验机

产品二维码
参   考   价: 120000
订  货  量: ≥1件
具体成交价以合同协议为准
  • 产品型号:
  • 品牌:
  • 产品类别:其他试验箱及气候环境设备
  • 所在地:上海市
  • 信息完整度:
  • 样本:
  • 更新时间:2021-06-25 17:14:05
  • 浏览次数:14
收藏
举报

联系我时,请告知来自 淘生意平台

上海鼎徵仪器仪表设备有限公司

代理商

标准会员·4年
  • 经营模式:代理商
  • 商铺产品:484条
  • 所在地区:上海上海市
  • 注册时间:2021-06-07
  • 最近登录:2022-02-08
  • 联系人:谢文清 (销售经理)
  • 电    话:13472521719
产品简介
  • 规格 1200x1000x1200mm 用途 热冲击试验

上海鼎徵仪器仪表设备有限公司代理销售Ford FLTM BI107-05涂层附着力热冲击试验机
This procedure is used to determine the resistance to coating adhesion loss of coated surfaces of aluminum,plastic, steel, and other substrates when su

详情介绍

E1

e2

e3
Ford FLTM BI107-05涂层附着力热冲击试验机 

Ford FLTM BI107-05涂层附着力热冲击试验机

 

                                                   Application
This procedure is used to determine the resistance to coating adhesion loss of coated surfaces of aluminum,plastic, steel, and other substrates when subjected to a wet blast similar to that produced by vehicle wash equipment.

 

 

                           Apparatus and Materials Required
Film Thickness Gauge
      per Ford Laboratory Test Method BI 117-01
Carbide Tip Scribe
      CTS (General Scribe #CM 88) - or equivalent
     12015 Telegraph Rd.
     Detroit, Michigan U.S.A.
     (313) 531-7668
Utility Knife
      Stanley, Quick Point 10-300 - or equivalent
     (break away tips)
Water Immersion Tank
     Per Ford Laboratory Test Method BI 104-01
    Note:  Thermal shock testing requires:
        a.  38 +/- 2 °C water temperature
        b.  5 ppm maximum dissolved solids
Heater/Circulator
       Fisher Scientific 13-874-70J - or equivalent
Dissolved Solids Meter
      Myron L Company - or equivalent
      833 East Broadway
      San Gabriel, California
Freezer
      Capable of minus 29 +/- 2 °C temperature

Steam Generator
   a.  Input flow of water to be 2.7 +/- .1 L/min (*).
   b.  Nozzle diameter to be 12.5 +/- .3 mm ID and at least 100 mm long.
   c.  Discharge dynamic head to be 37.9 +/- 1.9 kPa measured 25 mm from the nozzle  using 
       a   4.7 mm ID tube. A substantially non-diverging discharge is required for this test (**) 
    (***) (see Figures 1 and 2).
Note:  Electro-Magic Model 100 (and the earlier Model 60) Steam Generator available only 
      from:Atomic Cleaning Systems, 31651 West Eight Mile Road, Livonia, MI 48150, Phone: 
       (248) 615-4400, has been found to be satisfactory. The Model 100 or Model 60 are no 
       longermanufactured directly by Electro-Magic. However, Atomic Cleaning Systems is
       capable ofmodifying new Electro-Magic models to meet the Model 100 specifications
       required for this test.Milwaukee 1/2 inch globe valve No. 1151-1161, 150 SWP 300 WOg
      is adequate for use in  standardization of generator.
Model 100 Steam Generator
    The pumping pressure is directly related to the input flow rate. The pressure needed for
        therequired flow can be determined by measuring the pump pressure and discharge
        flow rate withthe burner off. When the burner is turned on, the required flow rate is
        obtained by readjusting to the required pump pressure.
    This is done by placing the tube midstream 25 mm from the nozzle. The tube size must  
         not bevaried because the densities and velocities are not uniform throughout the cross
        section of thedischarge stream.
  Adjusting the discharge dynamic head may be required. This must be done in such a
      way thatthe input flow rate as specified in Para (a) above is maintained. This is done by
     adjusting the amount of heat transferred to the water. Increasing the heat will cause the
     flow rate (pressure) of (a) to change. It must be readjusted. This operation will result in an
      increased dynamic pressure; to decrease it, decrease the heat and then adjust the flow
    (pressure).

Thermometer
       Capable of measuring 100 +/- 2 °C
Face Mask
      Full face cover safety mask is required when performing this test.
Gloves
     Gauntlet-type gloves for protection of hands are required.


                                    Conditioning and Test Conditions
  All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 ??C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

                                                          Procedure
1.  Standardize the Model 60 or Model 100 Steam Generator.
    a.  Measure and maintain the input flow at 2.7 L/min. Install a 12.5 mm globe valve in the
        steam line between coil weld assembly and a 5/32 inch hose nipple. With burner off,
         engage pump and adjust globe valve until 2.7 L/min is obtained.
        Record the tank pressure that is obtained with the 2.7 L/min flow rate. (This induced
         back pressure simulates the pressure that steam exerts on the system while the burner
         is on.)
   b.  Measure and maintain the mean dynamic head at 37.9 kPa (5.5 psi) using the fixtures as
       described in Figures 1 and 2. Open globe valve and turn on the burner. Allow tank
       pressure   tostabilize before reading the mean dynamic head. Adjustments of the
       dynamic head are to be  made by changing the amount of heat transferred to the water
       at the burner. (The flow  rate, as  specified above, must be maintained.)
    c.  Measure and maintain a 98 +/- 2 °C temperature of the steam blast at the test
        sitedistance.

2.    Measure film thickness per Ford Laboratory Test Method BI 117-01 at proposed test sites
     and record.
3.  Immerse the parts or panels (previously prepared per Engineering Materials Specification)
     in the water immersion tank for four hours at 38 +/- 2 °C. Aerate the water by placing 6.5
     mm ID plastic tube at the bottom of the tank and bubble air at a rate of one bubble per
     second minimum. Maintain a 5 ppm maximum dissolved solids (as NaCl) in the water.
     Check and record NaCl level using a dissolved solids meter.
4.  Remove the samples after four hours of water immersion and cut an "X" through the
      coating into the substrate across the panel or part where feasible (see Figure 3).
      a.  Use a scribe to make the cut if the substrate is metal or hard, rigid plastic.
      b.  Use a utility knife to make the cut if substrate is an elastomeric material.
5.  Place the test samples in a freezer at minus 29 +/- 2 °C for a three hour minimum freeze
    cycle.
6.  Within 30 seconds from freezer removal, direct the steam blast at the center of the "X" cut,
    at a distance  of 2 to 3 inches and 45° to the sample, in the direction shown in Figure 3.

 Note:  High pressure wet steam represents a potential safety hazard. Not only is it necessary|
            to secure the samples properly, but full face protection and gloves are required.
7.  After 30 seconds, record area (mm2) of coating removal by visually measuring with a
      metric ruler  (typical triangular coating removal: Area = 1/2 Base x Height). Also examine
      the surface and report  any blushing, whitening, or loss of gloss.
8. If a failure occurs, note number of seconds after steam black initiated that the failure 
      occurred.


Chemicals, materials, parts, and equipment referenced in this document must be used and handled properly.
Each party is responsible for determining proper use and handling in its facilities.
                                                     ATTACHMENT ONE
                                                      RATING SCALE FOR
                                             THERMAL SHOCK TEST PANELS

                                                    RATING               PEEL BACK
                                                            20      =       No removal
                                                            19      =       < 0.5 cm^2
                                                            18      =       < 1.0 cm^2
                                                            17      =       < 1.5 cm^2
                                                            16      =       < 2.0 cm^2
                                                            15      =       < 2.5 cm^2
                                                            14      =       < 3.0 cm^2
                                                            13      =        < 3.5 cm^2
                                                            12      =        < 4.0 cm^2
                                                            11      =        < 4.5 cm^2
                                                            10      =        < 5.0 cm^2
                                                             9       =         < 5.5 cm^2
                                                             8       =         < 6.0 cm^2
                                                             7       =         < 6.5 cm^2
                                                             6       =         < 7.0 cm^2
                                                             5       =         < 7.5 cm^2
                                                             4       =         < 8.0 cm^2
                                                             3       =         < 8.5 cm^2
                                                             2       =         < 9.0 cm^2
                                                             1       =         < 9.5 cm^2
                                                             0       =          > 9.5 cm^2
                                  SEE SPECIFICATION FOR ACCEPTANCE CRITERIA RATING

 

undefined

                                                        Figure 1

undefined
 

                                                         Figure 2

 undefined

                                                                 Figure 3

undefined

                                                    Figure 4

上一篇: DIN55662/ISO16925高压蒸汽喷射试验箱
下一篇: GMW 15919Thermal Shock Test for Pain
我要评论
文明上网,理性发言。(您还可以输入200个字符)

所有评论仅代表网友意见,与本站立场无关。

请选择省份

  • 安徽
  • 北京
  • 福建
  • 甘肃
  • 广东
  • 广西
  • 贵州
  • 海南
  • 河北
  • 河南
  • 黑龙江
  • 湖北
  • 湖南
  • 吉林
  • 江苏
  • 江西
  • 辽宁
  • 内蒙古
  • 宁夏
  • 青海
  • 山东
  • 山西
  • 陕西
  • 上海
  • 四川
  • 天津
  • 新疆
  • 西藏
  • 云南
  • 浙江
  • 重庆
  • 香港
  • 澳门
  • 台湾
  • 国外
=
同类优质产品

在线询价

X

已经是会员?点击这里 [登录] 直接获取联系方式

会员登录

X

请输入账号

请输入密码

=

请输验证码

收藏该商铺

X
该信息已收藏!
标签:
保存成功

(空格分隔,最多3个,单个标签最多10个字符)

常用:

提示

X
您的留言已提交成功!我们将在第一时间回复您~